Comen C30 Emergency & Transport Patient Monitor
ZK110,399.86
Shipping & Delivery
- Personal delivery
We will personally deliver to the specified address
1-2 Weeks
Free Delivery
- Private Courier delivery
Private courier (Falcon Express, Platnium or courier of your choice) will deliver to the specified address
1-2 Weeks
Free Delivery
- 6 months Warranty
- Free 1 week returns
Black Friday Blowout!
Description
The C30 Transport patient monitor is strong, stable, waterproof, dustproof, anti-fall and shockproof, it is Small and lightweight and easy to carry. It can be equipped with a optional specialized bag for first aid monitoring. Suitable for emergency scene, out-of-hospital transport, intra-hospital transport, bedside monitoring in the emergency department
Description
SpecificationsPatient: adult, pediatric, neonateDisplay: 4.3 ?color TFT touch screenResolution: 16:92 curves on screenSweep speed: 12.5mm / s, 25mm / s, 50mm / sIndicators:? Battery indicator light? Dual indicator alarm lightQRS beep and alarm soundKey soundAC input socketMDRTrend: 48 hoursAlarm: user adjustable high and low limitsConnection to the monitoring centerDVI connection
BreathingImpedance methodRate:? Adult 0-1OOrpm? Neonatal 0-150 rpm? Resolution: ? 1 rpmApnea alarm: 10s-40sAudible and visual alarmSweep speed: 12.5.25mm/sGain selection: x0.25, x0.5, x1, x2
ECGCable: 12-lead CardioTecTM,3 or 5 snaps (selectable)12 leads: I, Il, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, -V65 wire: RA, LA, RL, LL, V or R, L, N, F, C,3 wire: RA, LA, LL or R, L, FLead Selection: 12 leads: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V65 wire: I, Il, IIl, aVR, aVL, aVF, V3 wire: I, Il, IIIGain selection: x0.25, x0.5, x1, x2, autoAdult: 15-300 1 / minPediatric / neonate: 15-350 1 / minAccuracy: ? 1% or ? 1 1 / min (whichever is greater)Resolution: 1 1 / minECG bandwidth:MON: 0.5-55HzDIA: 0.05-150 HzOPE: 1-20HzST segment detection: ? 2.0mV (automatic)Arrhythmia AnalysisPacemaker pulse detection
Temperature2 channelsStandard sensor: CutaneousMeasurement range: 0-50 ? CResolution: 0.1 ? CAccuracy: 0.1 ? C (excludes sensor error)Channel: T1, T2, TD (temperature difference)
PNIMeasurement method: Automatic oscillometricWorking mode: manual / automatic / continuousInterval: Adjustable from 1 min to 480 minMeasurement types: systolic, diastolic, meanUnit of measure: mmHg / KPa, adjustableSystolic pressure range:? Adult: 40 to 270 mmHg? Pediatric: 40 to 200mmHg? Neonate: 40 to 135 mmHgDiastolic pressure range:? Adult: 10 to 215 mmHg? Pediatric: 10 to 150mmHg? Neonate: 10 to 100 mmHgMedium pressure range:? Adult: 20 to 235 mmHg? Pediatric: 20 to 165mmHg? Neonate: 20 to 110 mmHgOverpressure Protection: Hardware and Software? Accuracy: less than ? 5mmHg? Resolution: 1mmHg
Sp02 ComenRange: 1-100%Resolution: 1%Accuracy:? ? 2% (70-100%, Ped, no movement)? ? 3% (70-100%, Neo, no movement)? 0-69% unspecifiedRange alarm: 0-100%Pulse Frequency:? Range: 20 to 300 ppm? Resolution: 1 ppm? Accuracy:? ? 3ppm (no movement)? ? 5ppm (movement)Alarm: 20 to 300 ppm
EtCO2Sidestream CO2 (SideStream)Range: 0 to 150 mmHg, 0 to 79%,? 0 to 20 kPa (at 760 mmHg)? Accuracy: ? 2mm Hg (0-40mmHg)? ? 5% of reading (41-70 mmHg)? ? 8% of reading (71-100 mmHg)? ? 10% of reading (101-150 mmHg)Frequency: 0-120 rpmAccuracy:? ? 2rpm (0-70rpm)? ? 5 rpm (> 70 rpm)Response time: <240 ms (10% to 90%)Delay time: 70 rpm)Delay time: <2s